Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > ENTRANCE CABLE
Sort By:
1 2
Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire
Southwire Compact Stranded 8000 2-2-4-6X500AL USE Service Entrance Cable, Aluminum Conductor
Our Price: $2.39

Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed. more info
Southwire SEU Service Entrance Cable Wire
CABLE SEU COPPER 6/6/6CX150FT
Our Price: $4.29

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. more info
Southwire MBL Service Entrance Cable Wire
Southwire Compact Stranded 8000 4/04/02/04X500MBL Service Entrance Cable, 4 -Conductor, Aluminum Conductor, 600 V
Our Price: $4.99

Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed. more info
Southwire SEU Service Entrance Cable
Southwire 4/0-4/0-2/0 ALUM Service Entrance Cable, 3 -Conductor, Aluminum Conductor, PVC Insulation, Gray Sheath
Our Price: $5.39

Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. more info
Southwire 4/04/04/02/0X500 Service Entrance Cable Wire
Southwire Compact Stranded 8000 4/04/04/02/0X500 Service Entrance Cable, 4 -Conductor, Aluminum Conductor, 600 V
Our Price: $6.49

Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed. more info
Southwire SER Service Entrance Cable
Southwire 4/0-4/0-4/0-2/0 A Service Entrance Cable, 4-Conductor, 500 ft L, Aluminum Conductor, PVC Insulation, 600 V
Our Price: $6.99

Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 deg C. 600 V maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. more info
Southwire SEU Service Entrance Cable Wire
Southwire 2/2/2CX100 Service Entrance Cable, 3 -Conductor, Copper Conductor, PVC Insulation, Gray Sheath, 600 V
Our Price: $13.99

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F. more info
Southwire SEU Service Entrance Cable
Southwire 6/6/6AX500 Service Entrance Cable, 3 -Conductor, Aluminum Conductor, PVC Insulation, Gray Sheath, 600 V
Our Price: $599.99

Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. more info
Southwire SEU Service Entrance Cable
Southwire 2/2/2AX500 Service Entrance Cable, 3 -Conductor, Aluminum Conductor, PVC Insulation, Gray Sheath, 600 V
Our Price: $1,199.99

Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. more info
Southwire SER Service Entrance Cable
Southwire 2/2/2/4AX500 Service Entrance Cable, 4 -Conductor, Aluminum Conductor, PVC Insulation, Gray Sheath, 600 V
Our Price: $1,299.99

Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 deg C. 600 V maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. more info
   
 
1 2