Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES > BREAKER BOXES
Sort By:
1 2 3 ... 11
Square D QO2L30SC Load Center
Square D QO2L30SC Load Center, 120/240 VAC, 30 A, QO Main lug
Our Price: $17.35

Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed.
Homeline Square D HOM24L70S Load Center
Homeline Square D HOM24L70S Load Center, 120/240 VAC, 70 A, Main lug
Our Price: $17.85

Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM24L70F Load Center
Homeline Square D HOM24L70F Load Center, 120/240 VAC, 70 A, Main lug
Our Price: $17.85

Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed.
Eaton BR24L70SP Load Center
Eaton BR24L70SP Load Center, 120/240 VAC, 70 A, Main Lug
Our Price: $18.89

Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
Eaton BR24L70FP Load Center
Eaton BR24L70FP Load Center, 120/240 VAC, 70 A, Main Lug
Our Price: $18.89

Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
PowerMark Gold TL412C Standard Load Center
PowerMark Gold TL412C Standard Load Center, 120/240 VAC, 125 A, Main Lug
Our Price: $19.45

Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed.
Cutler Hammer BRL200 Main Lug Kit
Cutler Hammer BRL200 Main Lug Kit, 120/240 VAC, 200 A, 2 Pole, 1 - 300 KCMIL
Our Price: $19.95

Two pole - 200 amp - pair.
Square D QO24L70S Load Center
Square D QO24L70S Load Center, 120/240 VAC, 70 A, QO Main lug
Our Price: $22.09

Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed.
Eaton BR48L125FP Load Center
Eaton BR48L125FP Load Center, 120/240 VAC, 125 A, Main Lug
Our Price: $22.69

Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Eaton BR48L125SP Load Center
Eaton BR48L125SP Load Center, 120/240 VAC, 125 A, Main Lug
Our Price: $23.05

Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
   
 
1 2 3 ... 11