Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > ENTRANCE CABLE
Sort By:
1 2
Southwire SEU Service Entrance Cable
Southwire SEU Service Entrance Cable, 2-2-2 AWG, 200 ft, XHHW-2, THWN
Our Price: $330.00

Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable
Southwire SEU Service Entrance Cable, 4/0-4/0-4/0 AWG, 100 ft, XHHW-2, THWN
Our Price: $379.00

Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire
Southwire SEU Service Entrance Cable Wire, 6-6-6 AWG, 150 ft, XHHW, THHN/THWN
Our Price: $382.50

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable
Southwire SEU Service Entrance Cable, 6-6-6 AWG, 500 ft, XHHW-2, THWN
Our Price: $437.09

Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements.
Southwire SEU Service Entrance Cable Wire
Southwire SEU Service Entrance Cable Wire, 6-6-8 AWG, 200 ft, XHHW, THHN/THWN
Our Price: $458.00

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire
Southwire SEU Service Entrance Cable Wire, 8-8-8 AWG, 250 ft, XHHW, THHN/THWN
Our Price: $487.50

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire
Southwire SEU Service Entrance Cable Wire, 4-4-4 AWG, 150 ft, XHHW, THHN/THWN
Our Price: $682.50

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire
Southwire SEU Service Entrance Cable Wire, 2-2-2 AWG, 100 ft, XHHW, THHN/THWN
Our Price: $705.00

Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable
Southwire SEU Service Entrance Cable, 2-2-2 AWG, 500 ft, XHHW-2, THWN
Our Price: $811.15

Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements.
Southwire SER Service Entrance Cable
Southwire SER Service Entrance Cable, 2-2-2-4 AWG, 500 ft, XHHW-2, THWN
Our Price: $910.25

Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 degrees Celsius. 600 volt maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements.
   
 
1 2